1-800-235-7500 info@curbellmedical.com

NON-POWERED REACTIVE BED MATTRESSES AND COVERS

Our non-powered reactive mattresses offer a high level of comfort and additional protection against skin breakdown. Inside is a series of interconnected air cells that deliver dynamic response to patient movement without electricity or loud motors.  They feature memory foam on the top layer of the entire mattress.

A sloped heel section helps provide comfort to pressure points, and firm foam sides give extra support when a patient is sitting on the edge of the bed. The cover is polycarbonate and the interior comes standard with a fire barrier which gives them a fire rating of CAL129/FED1633.

FEATURES

WATERFALL ZIPPER FLAP

The waterfall zipper flap covers the zipper, so fluids pass over it without absorbing into the mattress.

RF WELDED SEAMS

Rather than a sewn seam, our seams are sealed using radio frequency welding to prevent fluid ingress. (Only available on polycarbonate material.)

PERFECT FIT

All our mattresses are accurately made to be a perfect fit on your beds.

BI-DIRECTIONAL STRETCH

Our breathable, two-way stretch fabric gives  added comfort and durability, and also prevents “hammocking,” allowing for easier patient transfer.

POLYCARBONATE FABRIC

Our mattresses feature a durable anti-microbial polyester-coated knit with a polycarbonate additive. This material is resistant to bleach and peroxide. Our standard mattress is also available in polyurethane material which is less expensive, but less durable and not resistant to bleach and peroxide. 

FED 1633 FIRE RATING

All our foam meets Fed 1633 fire safety standards.

CLAMSHELL ZIPPER

Our non-powered reactive mattresses feature a clamshell zipper that goes around three sides, making replacement of the cover easy.

FIVE YEAR WARRANTY

We stand behind all our bed mattresses with a five year warranty.

THOROUGH TESTING

All of our mattresses are tested by Support Surface Standards Initiative (S3I). Visit https://npiap.com/page/S3I for more information on this organization.

MADE IN THE USA

All of our mattresses are manufactured in the USA.

MEMORY FOAM

Memory foam allows the patient to be immersed into the mattress, which reduces pressure to body regions that are susceptible to pressure injuries.

SLOPED HEEL SECTION

Our Non-Powered Reactive mattresses feature a sloped heel section to help provide pressure point comfort.

AIR CELLS

Our non-powered reactive mattresses contain a series of interconnected air cells that deliver dynamic response to patient movement without electricity or loud motors.

CONSTRUCTION

PART NUMBERS

WIDTHLENGTHTHICKNESSPATIENT WEIGHT LIMITFULL MATTRESSMATTRESS COVER
36"80"7.25"550 Pounds2724927258
36"84"7.25"550 Pounds2725027259

CLEANING TIPS

Mattress disinfection is an important part of any hospital’s infection control program. But the harsh chemicals that are used can damage the mattress over time. Follow these tips to get the most out of your stretcher mattresses.

FOLLOW THE INSTRUCTIONS

Make sure you follow the instructions not just for whichever cleaning agent you’re using, but for the mattress itself. Not all mattresses are compatible with all common disinfectants, and using the wrong one can damage the mattress over time.

DILUTE IF NECESSARY

Some disinfectants are intended to be diluted before use. Using them at full strength can shorten the life of the mattress.

WAIT OUT THE “DWELL TIME”

The instructions for the disinfectant may mention the “dwell time”. This is the amount of time that a surface must remain wet to allow the chemical to be in contact with an organism in order to kill it. Make sure you let the disinfectant do its job before wiping it off.

RINSING IS A MUST

After the dwell time has been achieved, immediately rinse the surface with clean
warm water.

Contact us today for more information

Call us at 1-800-235-7500 or click the button below.